Given that the area of right triangle is 24 square centimeter, what is the functional relationship between Y and X? Combined with the actual situation, write out the value range of independent variable x The relation is y = 48 / X. I know. What's the range of values? X > 0? And when x=_____ The right triangle is an isosceles right triangle.

Given that the area of right triangle is 24 square centimeter, what is the functional relationship between Y and X? Combined with the actual situation, write out the value range of independent variable x The relation is y = 48 / X. I know. What's the range of values? X > 0? And when x=_____ The right triangle is an isosceles right triangle.


x. Y is the length of two right angles?
Combining with the actual situation, the value range of X is x > 0
When the triangle is isosceles right triangle, x = y = 48 / X
x^2=48
x=4√3



In an isosceles right triangle, the longest side is 10 cm long. How many square centimeters is the area of this triangle?


A: the area of this isosceles right triangle is 25 square centimeters



When the straight side of a right triangle is 10 and the square side is 10, e and D coincide. EFG moves at the speed of 2. The function of the overlapping area y and the time x is


Because of the triangle EBC, EB ^ 2 = EC ^ 2 + BC ^ 2
So 16 = x ^ 2 + (4x) ^ 2
16=17x^2
x^2=16/17
It is easy to get that triangle FDE is similar to triangle ECB, so if De is 3x, BC is 4x
So EC is X. using Pythagorean theorem, we get x ^ 2 = 16 / 17
Because area = (4x) ^ 2 = 256 / 17



The hypotenuse of a right triangle is 12 cm, the perimeter is 30 cm, and the area is calculated


Answer: 36. Let two right angle sides be x and Y respectively. The equations are: x square + y square = 12 square; X + y + 12 = 30. The solution is: (1) x = 12, y = 6 (2) y = 30 (rounding) s = 1 / 2 * 6 * 12 = 36



Why is the cross-sectional area of the wire used to transmit the same amount of electricity at 220 V to 110 V with the same transmission loss twice as small
What's the relationship between current and conductor


The electric quantity is directly proportional to the current, the electric quantity is the same, that is, the current is the same, u = IR, so the wire resistance R2 of 220 V should be twice that of 110 V wire resistance R1, and R = PL / S (P is the resistivity, l is the wire length, s is the wire cross-sectional area). Therefore, when other factors are the same, the cross-sectional area of 220 V wire is half that of 110 V wire



When the voltage of transmission line is high and the cross-sectional area of conductor is large, the voltage loss caused by reactance is larger than that caused by resistance


In fact, the voltage drop of high-voltage transmission line is very small, while the voltage drop of low-voltage transmission line is very large. For a specific line (with fixed resistance), the voltage drop of high-voltage transmission line is 5V, and that of low-voltage transmission line is 50V. In this way, the loss of high-voltage line is small, and that of low-voltage line is large



What is the meaning of "3l7:5 (vv-1 * 10) HDPE diameter 89 FC" in the construction drawing street lamp plane soil
I don't know what 3l7:5 and FC mean


3l7 is the loop number, 5 is five vv-1 * 10, FC is laid along the ground



NH - VV - 5x16 - sc50 - WC


NH: fire resistant
VV: copper conductor PVC insulated and sheathed power cable
5 * 16: five cores, each core has a cross-sectional area of 16mm2
Sc50: protective tube, diameter 50mm
WC, FC: laying method, WC is laid along the wall, FC is buried or laid in the floor



What does zr-vv-1 mean


The meaning of cable model: 4 is 4-core, Zr is flame retardant cable, VV is PVC insulated and PVC sheathed cable, and the following 1 is 1-core. This cable is a five core flame retardant PVC insulated and PVC protected cable, in which the 4-core is 150 square mm, and the 5-core is 95 square mm



Electrical diagram zr-bv-3 * 60 + E60 sc25 FC


ZR-BV flame retardant wire and cable
3 * 60 should be the conductor specification, three-phase, each phase section 60
SC stands for laying through water gas steel pipe and 25 stands for pipe diameter
Wp1: the first plug-in circuit in the distribution box